HP 34401A LABVIEW DRIVER

Instrument Driver Organization Once an instrument driver has been downloaded, the instrument driver VIs will be located on the Instrument Drivers palette. These VIs include the majority of the instrument driver template VIs, such as reset, self-test, revision, error query, and error message. Get acquainted with sub-vi’s. Launch the software Initialize the A Place the A in 4W-resistance measurement mode Switch the A to “local” mode so that the end user can adjust a trimpot until the desired resistance is obtained while seeing the resistance value change on the A Re-initialize the A when I need to switch to a different measurement Alternatively, is there a way to get the A to continuously display whatever measurement it’s taking while in remote mode? Both of these drives are supported by Agilent and come complete with example code for common tasks. LabVIEW instrument drivers simplify instrument control and reduce test program development time by eliminating the need for you to learn the complex, low-level programming commands for each instrument.

Uploader: Fenrigis
Date Added: 9 October 2004
File Size: 43.77 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 44572
Price: Free* [*Free Regsitration Required]

The Action VIs – initiate or terminate test and measurement operations, such as arming the trigger system or generating a stimulus. Rate this document Select a Rating 1 – Poor 2 3 4 5 – Excellent. Message 5 of 6. The Status VIs obtain the current status of the instrument or the status of pending operations.

Related Drivers  BROTHER DCP 7055 SCANNER DRIVER

Many thanks for the help. The alternative to using the NI Instrument Driver Finder is to go directly to the Instrument Driver Network and search for your instrument driver there.

Labview (Connected to instruments via PCI-GPIB ) to Study Diode Characteristics – Stack Overflow

The Close VI- terminates the software connection to the instrument and frees system resources. Open a blank vi. Message 7 of 7. No offense was taken. I hope not to offend NI people http: Message 3 of 7. I added h to the picture below for ONE method of logging until a specified time. Finally, the Simple Error Handler is called which indicates whether an error occurred.

Solved: Place HP A in Local Mode with GPIB-USB-HS – Discussion Forums – National Instruments

Message 3 of 4. Make sure that for each successful call to the Initialize VI, you use a matching Close VI to avoid maintaining unnecessary memory resources. They also have a CVI driver that can be converted. This site uses cookies to offer you a better browsing experience. Overview of Instrument Drivers An instrument driver is a set of software routines that control a programmable instrument.

The Data VIs- transfer data to or from the instrument.

Related Drivers  DEVICE USBPDO-7 DRIVER DOWNLOAD

Try the link below: Sign up using Facebook. Here’s my intended operation if it makes things more clear: Generally, you need to call the Close VI only once at the end of an application or when you finish communication with an instrument.

34970A/34972A LabView Programming Examples

Message 6 of 6. Usually the drivers are accessible and you will see all the GPIB calls that are made by the driver.

Message 2 of 4. Yes you can do this, but in principle you are writing your own driver. You can create instrument control applications and systems by programmatically linking instrument driver VIs on the block diagram. Most instrument drivers have menu palettes that include the following components. You can use an instrument driver for a particular instrument as is.

Post as a guest Name.

labbview Message 2 of 7. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type.

I apologize if I offended you. Klomp 1, 1 7 In this example, serial communication is used.